Line 29: Line 29:
| y || y || y || y || n || y || n || n
| y || y || y || y || n || y || n || n
| [http://www.ysihydrodata.com/pdfs/pdfs_02/600XL%20with%20vented%20level.pdf pdf]
| [http://www.ysihydrodata.com/pdfs/pdfs_02/600XL%20with%20vented%20level.pdf pdf]
-
| -- || --
+
| ?? || External 12VDC || RS232, SDI-12
|-
|-
! [http://www.ysihydrodata.com/ YSI Hydrodata]
! [http://www.ysihydrodata.com/ YSI Hydrodata]
Line 35: Line 35:
| y || y || y || y || n || y || n || n
| y || y || y || y || n || y || n || n
| [http://www.ysihydrodata.com/pdfs/pdfs_02/600XLM.pdf pdf]
| [http://www.ysihydrodata.com/pdfs/pdfs_02/600XLM.pdf pdf]
-
| -- || --
+
| 384K || 4 AA batteries, external 12VDC || RS232, SDI-12
|-
|-
! [http://www.ysihydrodata.com/ YSI Hydrodata]
! [http://www.ysihydrodata.com/ YSI Hydrodata]
Line 41: Line 41:
| y || y || y || y || y || y || n || y
| y || y || y || y || y || y || n || y
| [http://www.ysihydrodata.com/pdfs/pdfs_02/6820%20&%206920.pdf pdf]
| [http://www.ysihydrodata.com/pdfs/pdfs_02/6820%20&%206920.pdf pdf]
-
| -- || --
+
| 384K flash ROM || Batteries, external 12VDC || RS232, SDI-12
|-
|-
! [http://www.ysihydrodata.com/ YSI Hydrodata]
! [http://www.ysihydrodata.com/ YSI Hydrodata]
Line 47: Line 47:
| y || y || y || y || y || y || n || y
| y || y || y || y || y || y || n || y
| [http://www.ysihydrodata.com/pdfs/pdfs_02/6820.pdf pdf]
| [http://www.ysihydrodata.com/pdfs/pdfs_02/6820.pdf pdf]
-
| -- || --
+
| ?? || Batteries, external 12VDC || RS232, SDI-12
|-
|-
! [http://www.ysihydrodata.com/ YSI Hydrodata]
! [http://www.ysihydrodata.com/ YSI Hydrodata]
Line 53: Line 53:
| y || y || y || y || y || y || y || y
| y || y || y || y || y || y || y || y
| [http://www.ysihydrodata.com/pdfs/pdfs_02/6600sonde.pdf pdf]
| [http://www.ysihydrodata.com/pdfs/pdfs_02/6600sonde.pdf pdf]
-
| -- || --
+
| 384K || 8 C batteries, external 12VDC || RS232, SDI-12
|-
|-
! [http://www.rickly.com/ Rickly Hydrological Company]
! [http://www.rickly.com/ Rickly Hydrological Company]
| [http://www.rickly.com/wqi/Datasonde4A.htm Datasonde 4A]
| [http://www.rickly.com/wqi/Datasonde4A.htm Datasonde 4A]
| y || y || add-in || y || add-in || y || add-in || add-in
| y || y || add-in || y || add-in || y || add-in || add-in
-
| no spec sheet || -- || --
+
| no spec sheet || ?? || Batteries || RS232, SDI-12
|-
|-
! [http://www.sutron.com/ Sutron]
! [http://www.sutron.com/ Sutron]
| [http://www.sutron.com/products/multiparameterwaterquality.htm 5600-0703]
| [http://www.sutron.com/products/multiparameterwaterquality.htm 5600-0703]
| y || y || y || y || y || y || n || y
| y || y || y || y || y || y || n || y
-
| [http://www.sutron.com/pdfs/2006_MultiparameterSensor.pdf pdf] || -- || --
+
| [http://www.sutron.com/pdfs/2006_MultiparameterSensor.pdf pdf]
 +
| ?? || 4 or 8 AA batteries, 12VDC || RS232, RS485, RS422, SDI-12
|-
|-
! [http://www.campbellsci.ca/ Campbell Scientific] / [http://www.hydrolab.com/ Hach Environmental / Hydrolab]
! [http://www.campbellsci.ca/ Campbell Scientific] / [http://www.hydrolab.com/ Hach Environmental / Hydrolab]
Line 69: Line 70:
| ? || y || y || y || y || y || n || y
| ? || y || y || y || y || y || n || y
| [http://www.campbellsci.ca/Catalogue/Series_5_Specs.pdf pdf] || 512 KB memory
| [http://www.campbellsci.ca/Catalogue/Series_5_Specs.pdf pdf] || 512 KB memory
-
| 8 C batteries || RS 232, RS 485, and SDI-12
+
| 8 C batteries || RS 232, RS 485, SDI-12
|-
|-
! [http://www.campbellsci.ca/ Campbell Scientific] / [http://www.hydrolab.com/ Hach Environmental / Hydrolab]
! [http://www.campbellsci.ca/ Campbell Scientific] / [http://www.hydrolab.com/ Hach Environmental / Hydrolab]
Line 75: Line 76:
| ? || y || y || y || y || y || n || y
| ? || y || y || y || y || y || n || y
| [http://www.campbellsci.ca/Catalogue/Series_5_Specs.pdf pdf] || 512 KB memory
| [http://www.campbellsci.ca/Catalogue/Series_5_Specs.pdf pdf] || 512 KB memory
-
| 8 C batteries || RS 232, RS 485, and SDI-12
+
| 8 C batteries || RS 232, RS 485, SDI-12
|-
|-
! [http://www.campbellsci.ca/ Campbell Scientific] / [http://www.hydrolab.com/ Hach Environmental / Hydrolab]
! [http://www.campbellsci.ca/ Campbell Scientific] / [http://www.hydrolab.com/ Hach Environmental / Hydrolab]
Line 81: Line 82:
| ? || y || y || y || y || y || n || y
| ? || y || y || y || y || y || n || y
| [http://www.campbellsci.ca/Catalogue/Series_5_Specs.pdf pdf] || 512 KB memory
| [http://www.campbellsci.ca/Catalogue/Series_5_Specs.pdf pdf] || 512 KB memory
-
| 8 AA batteries || RS 232, RS 485, and SDI-12
+
| 8 AA batteries || RS 232, RS 485, SDI-12
|}
|}

Revision as of 23:36, 6 March 2007

Contents

Possible Commercial Product

http://store.pasco.com/pascostore/showdetl.cfm?DID=9&Detail=1&Product_ID=54417

Sensors

All-in-one Units, "Sondes"

Sonde Matrix (Incomplete, more rows and columns to be added)
Make Model Temp pH Redox (ORP) Cond Nitrate DO Sulfide Turbidity Specs Data Storage Power Interface Price
YSI Hydrodata 600 R y y n y n y n n no spec sheet -- --
YSI Hydrodata 600 XL y y y y n y n n pdf  ?? External 12VDC RS232, SDI-12
YSI Hydrodata 600 XLM y y y y n y n n pdf 384K 4 AA batteries, external 12VDC RS232, SDI-12
YSI Hydrodata 6920 y y y y y y n y pdf 384K flash ROM Batteries, external 12VDC RS232, SDI-12
YSI Hydrodata 6820 y y y y y y n y pdf  ?? Batteries, external 12VDC RS232, SDI-12
YSI Hydrodata 6600 y y y y y y y y pdf 384K 8 C batteries, external 12VDC RS232, SDI-12
Rickly Hydrological Company Datasonde 4A y y add-in y add-in y add-in add-in no spec sheet  ?? Batteries RS232, SDI-12
Sutron 5600-0703 y y y y y y n y pdf  ?? 4 or 8 AA batteries, 12VDC RS232, RS485, RS422, SDI-12
Campbell Scientific / Hach Environmental / Hydrolab DS5  ? y y y y y n y pdf 512 KB memory 8 C batteries RS 232, RS 485, SDI-12
Campbell Scientific / Hach Environmental / Hydrolab DS5X  ? y y y y y n y pdf 512 KB memory 8 C batteries RS 232, RS 485, SDI-12
Campbell Scientific / Hach Environmental / Hydrolab MS5  ? y y y y y n y pdf 512 KB memory 8 AA batteries RS 232, RS 485, SDI-12

Water Temperature

RTP - Ruggedized Wide Range Temperature Probe

The RTP temperature probe is designed for wide temperature range applications requiring excellent chemical resistant properties and sensor submersion.

pH

Redox Potential

Conductivity

Nitrate Levels (NO3?)

Dissolved Oxygen

Sulfide Concentrations

Turbidity

Batteries

Enclosures

Solar Panels

SBCs

Gumstix

Technologic Systems

Embedded Arm Product Matrix
SBC Type DIO lines A/D Converter Price
TS-7200 ARM 20 8 ch. 12-bit (opt) $149.00
TS-7250 ARM 20 5 ch. 12-bit $149.00
TS-7260 ARM 30 & XDIO* 2 ch. 12-bit $179.00
TS-7300 ARM 55 (35 XDIO) n/a $219.00
TS-7400 ARM 20 4 ch. 8 bit $129.00
TS-5500 x86 38 (IRQ) 8 ch. 8 bit $319.00